Ductless mini splits
AC repair
Furnace & heating
Heat pumps
Carrier
Trane
GoodmanSeasonal tune-up and full diagnostic on your Carrier, Trane, or Goodman system - readings shown to you before any repair is proposed
Diagnosis first, numbers second - you approve the repair price before a single part goes in.
Get your free estimateRheem Mini-Split Installation: The Marietta Owner’s Guide
We stock and install Rheem-compatible mini-split components across Marietta, with most replacement installations running $350 to $1,200 parts and labor included, depending on what failed and which Rheem series you own. Same-day service is often available when we have the part on the truck, which we usually do for the common failures. Most Marietta homeowners discover the problem the hard way: the indoor unit blowing warm air in July, water staining the drywall below the wall-mounted head, or an error code blinking on the display that won’t clear. The mini-split itself is rarely a total loss. It’s almost always one component, and matching that component to your specific Rheem model is what separates a fix that lasts from one that fails again in six months.

Which Rheem Models This Applies To
Rheem sells mini-splits under several series names you’ll find on the nameplate: the Classic Series, the Pro Series, and the heavier-built E Series. The nameplate is your best friend here. It’s a sticker on the side of the outdoor condenser or under the front cover of the indoor head, and it lists the model number, refrigerant type, and electrical specs. Write that down before you call anyone. We need it to match the right board, blower wheel, fan motor, or coil. Newer Rheem mini-splits built after the 2020 efficiency standards mostly run R-410A refrigerant, while the latest R-454B systems are beginning to show up in Marietta homes built in the last two years. Mixing components across series is where we see the most botched repairs: the Classic Series blower wheel does not fit the Pro Series head, even when both units are the same BTU rating. When Rheem OEM parts are available, we recommend them, especially for control boards and sensors where tolerance matters. For fan motors and simple mechanical parts, a quality aftermarket equivalent from a supplier we trust can save you 30% or more, and we will tell you which one we used and why.
Styles & brands we work with







Signs Your Rheem Mini-Split Installation Is Failing
- The indoor head blows air, but it’s warm or weakly chilled. This usually points to low refrigerant from a slow leak at a flare fitting, or a failing compressor capacitor. If refrigerant leaked out, there is a hole somewhere that must be found before recharging, or you’ll be back in the same spot next summer.
- Water drips from the indoor unit or stains appear on the wall below it. The condensate drain line clogs with Georgia’s humid-air fallout: dust, mildew, and sometimes the slime algae that loves our warm seasons. A clogged line backs water into the unit and onto your wallboard.
- The unit short-cycles: it starts, runs a few minutes, shuts off, repeats. This is often a failing thermistor (temperature sensor) or a control board that is misreading room temperature. Short-cycling drives up your power bill in Marietta’s hottest months and shortens compressor life.
- You hear a grinding, clicking, or rattling from the indoor head. A worn blower wheel bearing or debris in the blower cage. The longer it runs that way, the more likely the blower motor itself gets dragged into the repair bill.
- An error code blinks and will not clear with a power reset. Rheem units flash specific codes for specific failures, and guessing at the cause without reading the code properly leads to replacing the wrong part. We read codes, then confirm with a meter before we order or install anything.
See the difference
Before
After
Before
AfterReplacement Cost and What’s Included
Here’s what we actually charge for Rheem mini-split work in Marietta, written out so there are no surprises:
- Condensate drain cleaning or flush: $150 – $325, depending on access and how far the line runs
- Thermistor or small sensor replacement: $200 – $400, parts and labor
- Blower wheel or fan motor replacement: $350 – $750, depending on series and whether the motor is OEM or aftermarket
- Control board replacement: $400 – $900, with Rheem OEM boards at the higher end
- Full indoor head replacement (matched to existing outdoor unit): $900 – $1,800, installed and charged
Every price is written down and agreed to before we touch a screw. You get a line-item quote, not a lump sum with no explanation. The work itself carries our 365-Day Done Right Promise: if the part fails or the repair doesn’t hold within a year, we come back at no charge. No arguing, no re-diagnosis fee. We put that in writing on every invoice.
DIY or Call Us?
There are two things a homeowner can safely check. First, confirm the breaker is on and the thermostat or remote is set to cooling mode with fresh batteries. Second, look at the outdoor unit: if the coil is caked with pollen and cottonwood fuzz from a Marietta spring, that restriction alone can cause poor cooling. Cleaning the coil with a garden hose (power off, gentle spray) is a reasonable weekend task. Beyond that, this is not a DIY job. Mini-split systems hold pressurized refrigerant and 240-volt electrical connections. The flare fittings and the refrigerant charge are matched to factory spec, and a wrong move there can cause a slow leak, a compressor failure, or an electrical shock that nobody should risk. Devin Marlowe has spent the better part of three decades on HVAC systems across the South, and he’ll tell you the same: tell me what it’s doing, and I’ll tell you what it needs. No guesswork, no upsell. If you’re on the fence, call (478) 662-5175 and describe the symptom. We’ll tell you over the phone whether it’s worth a service call.

FAQs
Most Rheem mini-split components are built for 10 to 15 years of service, but Marietta’s humidity and pollen load shorten the lifespan of anything that moves air or drains water. Blower wheels and drain lines in our area often need attention at the 7 to 10 year mark. The compressor and control boards typically last as long as the unit itself if the system is kept clean and the filters are changed.
Some components, like clogged drain lines and dirty blower wheels, are cleanable and we do that all the time. Motors, boards, and sensors are replace-only items. We’ll tell you which one you’re facing and show you the failed part before we install the new one, if you want to see it.
Most single-part replacements on a Rheem mini-split take 1 to 3 hours on site, including testing the system through a full cooling cycle before we leave. Full indoor head replacements are usually a half-day job. We’ll give you a realistic window when you book, and we call before we arrive so you know exactly who is walking up to your door.
We stock the most common Rheem replacement parts on our trucks: drain line components, standard thermistors, capacitors, and blower wheels for the Classic and Pro Series. Less common parts, like series-specific control boards or E Series components, we order with overnight delivery in most cases. We’ll tell you upfront if there’s a parts wait, and what the timeline looks like before you commit to any work.
If your Rheem mini-split is acting up and you want a straight answer on what it will cost to fix, call Brandt HVAC Co Marietta at (478) 662-5175. We answer the phone with a live person, 24/7, and we’ll give you a written price before any work begins. Every technician who comes to your door is background-checked, identity-verified through the Threshold Verified standard, and you’ll get their name and photo before they arrive. We service Rheem, along with Carrier, Trane, and Lennox systems across Marietta and nearby areas. Free estimates, honest diagnostics, and a guarantee in writing on every repair we make.
Written by Devin Marlowe, Owner, Brandt HVAC Co Marietta at Brandt HVAC Co Marietta, serving Marietta and nearby areas.